SsangYong Kyron
Technical specifications of air conditioning and 2 documented fault patterns from real workshop repairs.
Most Common A/C Problems
Cabin blower does not work or works only on maximum speed
High Priority94%
Weak cabin coolingProblem visible at standstill or in trafficBlower works only on highest speedAir blows from incorrect vents
Details
Air conditioning stopped cooling / no response to AC button
High Priority90%
No cold air from ventsA/C does not react to control panel settings
Details
A/C Technical Specifications
| Variant | Refrigerant | Amount (g) | Oil | Oil (ml) |
|---|---|---|---|---|
| Standard | R134a | 600 –700g | PAG PAO 68 | 265ml |
Trouble with Kyron?
Our AI will analyze symptoms and generate a personalized diagnostic report.
Summary
- Documented faults
- 2
- Engine variants
- 1
- Average confidence
- 92%