Subaru Forester

Technical specifications of air conditioning and 13 documented fault patterns from real workshop repairs.

Most Common A/C Problems

A/C cooling is weak and gradually loses performance

High Priority100%
Problem visible at standstill or in trafficProblem appears while drivingSlow loss of refrigerant
Details

A/C works intermittently or cuts out during driving

High Priority100%
Air conditioning works intermittently
Details

Air conditioning stopped cooling / no response to AC button

High Priority95%
No cold air from vents
Details

Air conditioning stopped cooling / no response to AC button

High Priority96%
Air conditioning does not turn on
Details

Cabin blower does not work or works only on maximum speed

High Priority99%
Blower works only on highest speedWeak airflowUnusual noises when A/C is turned onMusty mold odor from vents
Details

No airflow from specific vents or clicking noise behind dashboard

High Priority95%
No blowing from ventsClicking or rattling behind dashboardUnusual noises when A/C is turned on
Details

A/C cooling is weak and gradually loses performance

High Priority99%
No cold air from vents
Details

Blower vents emit warm air when A/C is turned on

High Priority96%
No cold air from ventsFrost or ice on pipes under the hood
Details

Air conditioning stopped cooling / no response to AC button

High Priority98%
Irregular A/C operationAir conditioning does not turn on
Details

Air conditioning stopped cooling / no response to AC button

High Priority98%
Frost or ice on pipes under the hoodAir conditioning does not turn on
Details

A/C cooling is weak and gradually loses performance

High Priority99%
Weak cabin coolingVibrations or humming after turning on A/C
Details

Air conditioning stopped cooling / no response to AC button

High Priority99%
Air conditioning works intermittentlyAir conditioning does not turn on
Details

Hissing from vents and slow loss of refrigerant

High Priority96%
Musty mold odor from ventsSlow loss of refrigerant
Details

A/C Technical Specifications

VariantRefrigerantAmount (g)OilOil (ml)
V - (SK)R1234yf480-530gPAG YF ISO 46120 - 150ml
(SH)R134a500gPAG PAO 68 b.d.b.d.ml
(SG) 2,0 i/2,0 i Turbo/2,5 iR134a550 – 650gZXL200PG PAO 68 lub PAG ISO 100145ml
(SF) kierownica po lewej stronieR134a550 – 650gDH-PR PAO 68 lub PAG ISO 100 b.d.b.d.ml
(SF) kierownica po prawej stronieR134a650 –750gZXL200PG PAO 68 lub PAG ISO 100 b.d.b.d.ml
Open full refrigerant database

Trouble with Forester?

Our AI will analyze symptoms and generate a personalized diagnostic report.

Summary

Documented faults
13
Engine variants
5
Average confidence
98%